Examples#
The following worked examples use the bundled steel-frame test structure dataset
(tests/files/). Each is available as a plain Python script in scripts/
and as an interactive Jupyter notebook rendered here.
For a full description of the test structure, the 3D scanning laser vibrometer measurement technique, and the 15-setup scan arrangement, see Example data: steel frame with 3D scanning laser vibrometer.
Notebook |
Workflow |
|---|---|
One measurement setup → SSI-cov/ref → stabilisation → mode shapes |
|
15 setups → per-setup SSI → PoSER merge → global mode shapes |
|